Exposure of a pump’s wetted surface area to acids can result in leach out of trace metals. Trace metal contamination causes alteration of electrical properties in semiconductor devices. The wetted surface area of a Levitronix® pump is several times smaller than diaphragm pumps of comparable hydraulic power.
Test conditions
35 % HCl was used as extractant. Continuous flow of the exctractant was maintained through the pumps during each test. A background sample was taken prior to each test and further samples were taken at approximately even spaced time intervals on a logarithmic scale. The results of the analyses were converted to cumulative mass extracted.
Results
The surface contamination from diaphragm pumps compared to Levitronix® pumps was up to 9 times higher.
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |